Object Name: LTW-SHS-CSH-CONC_Wall-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2001G LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 17 13 OmniClass Title: Retaining Walls |
|
Object Name: LTW-SHS-CSH-GraniteWall-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2007E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 17 13 OmniClass Title: Retaining Walls |
|
Object Name: STE-OTR-CSH-Piezometer-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2005B LOD-G: 300 LOD-I: 300 OmniClass No.: 23-27 11 13 19 OmniClass Title: Pressure Indicators |
|
Object Name: GSM-CMS-CSH-CONC_Stair-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2101D, C 2103K LOD-G: 300 LOD-I: 300 OmniClass No.: 23-17 23 17 OmniClass Title: Stairs |
|
Object Name: GSM-SST-CSH-SteelStair-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2102/1, C 2102/2A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-17 23 17 OmniClass Title: Stairs |
|
Object Name: STE-OTR-CSH-TreeRing-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2104/1A , C 2104/2A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 27 13 21 OmniClass Title: Tree Grids |
|
Object Name: GSM-SON-CSH-SoilNail-01 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2106/1L, C 2106/2K LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 13 11 OmniClass Title: Earth Reinforcement Soil Nails |
|
Object Name: GSM-SON-CSH-SoilNail-02 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2106/1L, C 2106/3L LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 13 11 OmniClass Title: Earth Reinforcement Soil Nails |
|
Object Name: GSM-SON-CSH-SoilNail-03 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2106/1L, C 2106/4F, C 2106/5C LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 13 11 OmniClass Title: Earth Reinforcement Soil Nails |
|
Object Name: GSM-SON-CSH-SoilNail-04 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2106/1L, C 2106/6A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 13 11 OmniClass Title: Earth Reinforcement Soil Nails |
|
Object Name: GSM-SON-CSH-SoilNail-05 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2106/1L, C 2106/7B, C 2106/8 LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 13 11 OmniClass Title: Earth Reinforcement Soil Nails |
|
Object Name: GSM-SON-CSH-RockBolt-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2201D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 11 17 OmniClass Title: Stabilizing Ground Rock Bolts |
|
Object Name: GSM-SON-CSH-RockDowel-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2202D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 11 19 OmniClass Title: Stabilizing Ground Rock Anchors |
|
Object Name: GSM-SON-CSH-WallDowel-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2520A, C 2521A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 11 11 OmniClass Title: Retaining Stabilizing Ground Anchors |
|
Object Name: STE-OTR-CSH-FilterBlanket-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2302F LOD-G: 300 LOD-I: 300 OmniClass No.: 23-13 11 00 OmniClass Title: Loose Granular Fills, Aggregates, Chips, and Fibers |
|
Object Name: STE-OTR-CSH-SlopeCrestFill-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2302F LOD-G: 300 LOD-I: 300 OmniClass No.: 23-13 11 00 OmniClass Title: Loose Granular Fills, Aggregates, Chips, and Fibers |
|
Object Name: SWD-___-CSH-CutoffDrain-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2401F LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 13 OmniClass Title: Combination Storm Drain and Underdrain Inlets |
|
Object Name: SMH-___-CSH-Manhole-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2402D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: GSM-RKD-CSH-RakingDrain-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2403E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 13 11 OmniClass Title: Soil Stabilization Products |
|
Object Name: GSM-SCH-CSH-CatchPit-01 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2405/1, C 2405/2, C 2405/3, C 2405/4, C 2405/5 LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: GSM-SCH-CSH-CatchPit-02 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2406/1, C 2406/2A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: STE-STU-CSH-CatchPitCover-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2407B LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: GSM-SCH-CSH-CatchPit-03 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2408D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: GSM-SUP-CSH-UChannelA-01 Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2409I LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: GSM-SUP-CSH-Connection-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2409I LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: GSM-SUP-CSH-UChannelB-01 Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2410I LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: GSM-SUP-CSH-UChannelB-02 Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2410I LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: GSM-SUP-CSH-UChannelUpStand-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2509A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: GSM-SSP-CSH-SteppedChannel-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2411G LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: STE-STU-CSH-CONC_Cover-03 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2412E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: STE-STU-CSH-CI_Cover-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2412E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 13 19 OmniClass Title: Surface Water Drainage Systems |
|
Object Name: GSM-SUP-CSH-UChannelAndBox-__ Software Version: Civil3D 2020 Ref. Standard Drawing No.: C 2415D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-39 29 15 OmniClass Title: Waste Water Channels, Gullies, Gratings, Covers |
|
Object Name: SPQ-OTR-CSH-PrismAdaptor-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2513A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-19 00 00 OmniClass Title: Specialty Products |
|
Object Name: STE-STU-CSH-DisplaySign-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2505/1C, C 2505/2C, C 2506D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-19 11 11 OmniClass Title: Information Signs |
|
Object Name: STE-STU-CSH-SettleSign-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2512A LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 00 00 OmniClass Title: Site Products |
|
Object Name: GSM-FBR-CSH-WireMeshToRock-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2205F LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 13 11 OmniClass Title: Soil Stabilization Products |
|
Object Name: GSM-TMW-CSH-TempFenceA-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2501/1D, C 2501/2C LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 25 19 19 OmniClass Title: Chain Link Metal Fences |
|
Object Name: GSM-TMW-CSH-TempFenceB-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2502/1E, C 2502/2E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 25 19 19 OmniClass Title: Chain Link Metal Fences |
|
Object Name: GSM-SGA-CSH-Gate-01 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2508E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 25 15 17 OmniClass Title: Swinging Gates |
|
Object Name: GSM-SGA-CSH-Gate-02 Software Version: Revit 2020 Ref. Standard Drawing No.: C 2510E LOD-G: 300 LOD-I: 300 OmniClass No.: 23-11 25 15 17 OmniClass Title: Swinging Gates |
|
Object Name: GSM-TMW-CSH-TempSTL-__ Software Version: Revit 2020 Ref. Standard Drawing No.: C 2504D LOD-G: 300 LOD-I: 300 OmniClass No.: 23-17 23 15 OmniClass Title: Ladders |
|
Disclaimer : The BIM objects are for modelling purpose and reference only. CEDD will not be in any case held liable for any damage caused by the use, reference or adoption of the BIM Objects, including but not limited to any errors or omissions in any kind contained therein.